Determining the ion dose rate of the X-ray tube with molydenum anode

VP6.3.1.4
Determining the ion dose rate of the X-ray tube with molydenum anode
Determining the ion dose rate of the X-ray tube with molydenum anode Mean ion dose rate < j > as a function of the tube high voltage U, I = 1.0 mA (P6.3.1.4)
Determining the ion dose rate of the X-ray tube with molydenum anode

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟

Description

The aim of the experiments P6.3.1.3 and P6.3.1.4 is to detect X-rays using an ionization chamber. While experiment P6.3.1.3 focuses on the investigation of the saturation characteristics of the experimental setup, experiment P6.3.1.4 investigates the ion dose rate to quantify the effect of X-rays. The mean ion dose rate

is calculated from the ionization current Iion which the X-radiation generates in the irradiated volume of air V, and the mass m of the irradiated air. The measurements are conducted for various emission currents I and high voltages U of the X-ray tube.

Components of equipment sets

1 554800 X-ray apparatus LD
1 554861  8  X-ray tube, Mo LD
1 554840  8  Plate capacitor, X-ray LD
1 52227  4  Power supply, 450 V LD
1 53214  8  Electrometer amplifier LD
1 57702  4  Resistor, 1 GΩ, STE2/19 LD
2 531120 Multimeter LDanalog 20 LD
1 57524  4  Screened cable, BNC/4 mm Plug LD
2 500421  4  Connecting lead 19 A, 50 cm, red LD
2 500422  4  Connecting lead 19 A, 50 cm, blue LD
2 500424  8  Connecting lead 19 A, 50 cm, black LD
1 500441  4  Connecting lead 19 A, 100 cm, red LD
1 500442  4  Connecting lead 19 A, 100 cm, blue LD

Experiment Instructions

PDF (Experiment description) PDF (Experiment description) P6.3.1.4 Determining the ion dose rate of the X-ray tube with molydenum anode
Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us