X-ray apparatus, Mo, complete

LD 554801
X-ray apparatus, Mo, complete
  8  X-ray apparatus, Mo, complete

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟

Description

Fully-featured, microprocessor-controlled apparatus with molybdenum X-ray tube and goniometer designed for conducting a wide variety of experiments in X-ray physics. The high-voltage system, X-ray tube and experiment chamber are all contained within a radiation-proof housing. Designed as a school X-ray apparatus and fully protected equipment. The type approval is also valid for additional X-ray tubes (Fe, Cu, Ag, W, Au). The X-ray tubes are supplied already fully adjusted so that they can be easily interchanged. Utmost safety and operational comfort is ensured by automatic door locking, which unlocks the doors automatically, when no x-ray radiation is being generated.
Two large displays show all relevant information concerning the current experiment. The tube voltage and tube current can be set within the ranges 0 to 35 kV and 0 to 1 mA respectively. The built-in rate meter including enables direct measurement in conjunction with a Geiger-Müller counter tube. The X-ray apparatus can also be connected to a PC via the USB port (software included) for recording Bragg spectra. Alternatively, the two analogue outputs (counting rate and angular position) permit data acquisition using a chart recorder.
The goniometer (554 831) enables precise setting of any angular position of the sensor and the target as well as coupled 2:1 sensor and target motion, both manual and automatic angular scans are possible.
Two screened coaxial lead-ins and one free access duct provide access to the experiment chamber, e.g. for connecting an x-ray energy detector.
Device fully assembled and adjusted, ready for operation.

Technical data

  • School X-ray apparatus and fully protected equipment with German type approval for school use (approval no. BFS 05/07 V/SchRöV) (suitable for the operation with the interchangeable tubes: Fe, Cu, Mo, Ag, W, Au)
  • Dose rate at a distance of 10 cm: <1 µS/h
  • Two independent safety circuits for doors, high voltage and emission current (safety approval by TÜV Rheinland and according to requirement regulations for PTB 2005 type approval)
  • Automatic door locking: doors can be opened only, when no high voltage is present i.e. no X-ray radiation can be generated (safety approval by TÜV Rheinland and according to requirement regulations for PTB 2005 type approval)
  • High voltage: 0 ... 35.0 kV (regulated DC voltage)
  • Tube current: 0 ... 1.00 mA (independent regulated DC)
  • Visible X-ray tube with molybdenum anode for characteristic short-wave radiation:
    Kα = 17.4 keV (71.0 pm), Kβ = 19.6 keV (63.1 pm)
  • Fluorescent screen for transillumination experiments: d = 15 cm
  • Built-in rate meter including voltage supply for GM counter tube
  • Loudspeaker: for audible ratemeter
  • Two 4-digit displays (25 mm high) for displaying the following as desired: high voltage, anode current, counting rate, target/sensor angle, scanning range, step width, gate time
  • Goniometer (554 831), stepper-motor-controlled
    Operating modes: manual control and automatic scan for sensor only, target only, 2:1 coupling
    Angular range:
    Target unlimited (0° ... 360°)
    Sensor -10° ... +170° Step width: 0.1°
  • Exposure timer, gate time: 0.5 s ... 9999 s
  • Bushes in the experiment chamber: high-voltage coaxial cable, BNC coaxial cable, empty channel for e.g. tubing, cable etc.
  • Analogue outputs: each proportional to target angle and to counting rate for chart recorder connection
  • USB port for connecting a PC to control the X-ray apparatus, data recording and evaluation by the delivered Windows software
  • LabVIEW and MATLAB driver for Windows available free of charge at http:/www.ld-didactic.com for user defined controlling and measuring
  • Input voltage: 230 V (±10 %)/47 - 63 Hz
  • Power consumption: 120 VA
  • Dimensions: 67 cm x 48 cm x 35 cm
  • Weight: 41 kg

Scope of delivery

  • X-ray apparatus with molybdenum tube
  • Goniometer (554 831)
  • NaCl crystal (554 78), lattice spacing: 282 pm
  • Zirconium foil
  • Cover for fluorescent screen
  • Dust cover
  • USB cable
  • Software CASSY Lab 2 for X-ray Apparatus (524 223)
  • Product key for experiment description for online use in LeyLab and for offline use in the Document Center

1 55478  4  NaCl crystal for Bragg reflection LD
1 554800 X-ray apparatus LD
1 554831  8  Goniometer LD
1 554861  8  X-ray tube, Mo LD

Additionally required

1 55901  8  End-window counter with cable for α, β, γ and X-rays LD

Downloads

MSI MSI Software Computed Tomography (en, V2.11)
MSI MSI Software Computed Tomography (fr, V2.11)
Manual Manual Manual Computed Tomography (en)
Manual Manual Manual Computed Tomography (fr)
ZIP ZIP Frog example tomogram, CT module (300 µm, 16 MB)
ZIP ZIP Egg example tomogram, CT module (300 µm, 12 MB)
ZIP ZIP Indians example tomogram, CT module (300 µm, 50 MB)
ZIP ZIP Frog example tomogram, X-ray image sensor (96 µm, 52 MB)
ZIP ZIP Bug example tomogram, X-ray image sensor (96 µm, 60 MB)
ZIP ZIP Snail example tomogram, X-ray image sensor (96 µm, 62 MB)
ZIP ZIP Frog example tomogram, X-ray image sensor (48 µm, 450 MB)
ZIP ZIP Bug example tomogram, X-ray image sensor (48 µm, 450 MB)
ZIP ZIP Snail example tomogram, X-ray image sensor (48 µm, 470 MB)
MSI MSI CASSY Lab 2 for X-ray Apparatus (en, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (fr, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (es, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (pt, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (it, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (nl, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (ru, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
MSI MSI CASSY Lab 2 for X-ray Apparatus (zh, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for X-ray Apparatus
Manual Manual CASSY Lab 2 Manual (en)
Manual Manual CASSY Lab 2 Manual (fr)
Manual Manual CASSY Lab 2 Manual (es)
Web Link Web Link CASSY Lab 2 Web Help (en)
Web Link Web Link CASSY Lab 2 Web Help (fr)
Web Link Web Link CASSY Lab 2 Web Help (es)
ZIP ZIP CASSY SDK for own software development (Windows/Linux)
ZIP ZIP LabVIEW driver for LabVIEW 2017 or higher (Windows)
ZIP ZIP MATLAB driver with examples (Windows)

Videos


Up to now, the resolution available from school X-ray apparatuses could only record the characteristic lines in a Bragg spectrum with low sharpness. This meant that they became too wide and could only be measured with too small intensity in comparison wit

A CT scan with the the x-ray apparatus.
Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us